15 Technical data
15.1
Standards and operang condions
15.1.1 Conformies/approvals
Conformity
CE
2014/35/EU Low-Voltage Direcve
2014/30/EU EMC Direcve (reference: CE-typical drive system)
EAC
TR CU 004/2011 Eurasian conformity: safety of low voltage equipment
TR CU 020/2011
Eurasian conformity: electromagnec compability of technical
means
RoHS 2011/65/EU
Restricons on the use of certain hazardous substances in
electrical and electronic devices
Approval
UL UL 61800-5-1
for USA and Canada (requirements of the CSA 22.2 No. 274)
File No. E132659
15.1.2 Protecon of persons and device protecon
Degree of protecon
IP20 EN 60529
Data applies for operaonally ready mounted state and not in wire
r
ange of terminals
UL 50 Protecon against accidental contact only
Open type Only in UL-approved systems
Insulaon resistance
Overvoltage category III EN 61800-5-1 0 … 2000 m amsl
Overvoltage category II EN 61800-5-1 over 2000 m amsl
Isolaon of control circuits
Safe mains isolaon via double/reinforced
insulaon
EN 61800-5-1
Leakage current
> 3.5 mA AC, > 10 mA DC EN 61800-5-1 Please observe regulaons and safety instrucons!
Starng current
≤ 3 x rated mains current
Protecve measures against
Short circuit
Earth fault Earth-fault protected depending on operang status
Overtemperature of motor I²xt monitoring
Overvoltage
Motor stalling
15.1.3 EMC data
Noise emission
Category C2 EN 61800-3 See rated data
Category C3 EN 61800-3 See rated data
Noise immunity
Fullls requirements according to EN 61800-3
Operaon on public supply systems
Take measures to limit the expected radio
in
terference:
The machine or system manufacturer is responsible for
compliance with the requirements for the machine/system!
< 1 kW: With mains choke
EN 61000-3-2
> 1 kW for mains current ≤ 16 A: Without
addional measures
Mains current > 16 A: with mains choke or
mains lter, with dimensioning for rated
power.
EN 61000-3-12
Technical data
EMC da
ta
308