15 Technical data
15.1
Standards and operang condions
15.1.1 Conformies/approvals
Conformity
CE
2014/35/EU Low-Voltage Direcve
2014/30/EU EMC Direcve (reference: CE-typical drive system)
EAC
TR CU 004/2011 Eurasian conformity: safety of low voltage equipment
TR CU 020/2011
Eurasian conformity: electromagnec compability of technical
means
RoHS 2011/65/EU
Restricons on the use of certain hazardous substances in
electrical and electronic devices
Approval
UL UL 61800-5-1
for USA and Canada (requirements of the CSA 22.2 No. 274)
File No. E132659
15.1.2 Protecon of persons and device protecon
Degree of protecon
IP20 EN 60529
Data applies for operaonally ready mounted state and not in wire
r
ange of terminals
UL 50 Protecon against accidental contact only
Open type Only in UL-approved systems
Insulaon resistance
Overvoltage category III EN 61800-5-1 0 … 2000 m amsl
Overvoltage category II EN 61800-5-1 over 2000 m amsl
Isolaon of control circuits
Safe mains isolaon via double/reinforced
insulaon
EN 61800-5-1
Leakage current
> 3.5 mA AC, > 10 mA DC EN 61800-5-1 Please observe regulaons and safety instrucons!
Starng current
≤ 3 x rated mains current
Protecve measures against
Short circuit
Earth fault Earth-fault protected depending on operang status
Overtemperature of motor I²xt monitoring
Overvoltage
Motor stalling
15.1.3 EMC data
Noise emission
Category C2 EN 61800-3 See rated data
Category C3 EN 61800-3 See rated data
Noise immunity
Fullls requirements according to EN 61800-3
Operaon on public supply systems
Take measures to limit the expected radio
in
terference:
The machine or system manufacturer is responsible for
compliance with the requirements for the machine/system!
< 1 kW: With mains choke
EN 61000-3-2
> 1 kW for mains current ≤ 16 A: Without
addional measures
Mains current > 16 A: with mains choke or
mains lter, with dimensioning for rated
power.
EN 61000-3-12
Technical data
EMC da
ta
308