10.3 Congure digital outputs
10.3.1
Relay output
Sengs for the relay.
Relay only switches if the inverter is supplied with 240 V or 400 V.
Use a c
orresponding suppressor circuit in case of an inducve or capacive
load!
Details
The relay is controlled with the trigger selected in 0x2634:001
(P420.01).
The following sengs are possible for the relay:
•
Inversion
①
•
Switch-on delay
②
•
Cutout delay
③
COM
NC
NO
0x4018:0050x4018:006
1
0
1
0x2635 001: 0x4018 004: 0x4018:003
0x2634:001
X9
0x4018:007
Trigger
Diagnosc parameters:
•
The logic s
tatus of the trigger signal is displayed in 0x4018:006.
•
The logic status of the relay is displayed in 0x4018:005.
•
The current switching cycles of the relay are shown in 0x4018:007.
Parameter
Address Name / seng range / [default seng] Informaon
0x2634:001
(P420.01)
Digital outputs funcon: Relay
(Dig.out.funcon: Relay
funcon)
Assignment of a trigger to the relay.
Trigger = FALSE: X9/NO-COM open and NC-COM closed.
Trigger = TRUE: X9/NO-COM closed and NC-COM open.
Notes:
•
An inversion set in 0x2635:001 (P421.01)is taken into consideraon
here.
0 Not connected No trigger assigned (trigger is constantly FALSE).
1 Constant TRUE Trigger is constantly TRUE.
11 Digital input 1 State of X3/DI1, taking an inversion set in 0x2632:001 (P411.01) into
consideraon.
12 Digital input 2 State of X3/DI2, taking an inversion set in 0x2632:002 (P411.02) into
consideraon.
13 Digital input 3 State of X3/DI3, taking an inversion set in 0x2632:003 (P411.03) into
consideraon.
14 Digital input 4 State of X3/DI4, taking an inversion set in 0x2632:004 (P411.04) into
consideraon.
15 Digital input 5 State of X3/DI5, taking an inversion set in 0x2632:005 (P411.05) into
consideraon.
50 Running TRUE if inverter and start are enabled and output frequency > 0 Hz.
Otherwise FALSE.
Excepon, quick stop mode: TRUE if inverter and start are enabled and
output frequency > 0.2 Hz. Otherwise FALSE.
51 Ready for operaon TRUE if inverter is ready for operaon (no error acve, no STO acve and
DC-bus voltage ok). Otherwise FALSE.
TRUE, wenn Inverter betriebsbereit (kein Fehler akv und
Zwischenkreisspannung ok). Sonst FALSE.
52 Operaon enabled TRUE if inverter and start are enabled. Otherwise FALSE.
53 Stop acve TRUE if inverter is enabled and motor is not started and output
frequency = 0.
I/O extensions and control connecons
Congure digital outputs
R
elay output