Address Name / seng range / [default seng] Informaon
54 Quick stop acve TRUE if quick stop is acve. Otherwise FALSE.
55 Inverter disabled (safety) TRUE if the integrated safety system has inhibited the inverter.
Other
wise FALSE.
Not available
56 Fault acve TRUE if error is acve. Otherwise FALSE.
57 Error (non-reseable) acve TRUE if non-reseable error is acve. Otherwise FALSE.
58 Device warning acve TRUE if warning is acve. Otherwise FALSE.
A warning has no impact on the operang status of the inverter.
A warning is reset automacally if the cause has been eliminated.
59 Device trouble acve TRUE if a fault is acve. Otherwise FALSE.
In the event of a fault, the motor is brought to a standsll with the
quick stop ramp. The inverter is then disabled.
Excepon: In case of a serious fault, the inverter is disabled
immediately. The motor has no torque (coasts).
The error state will be le automacally if the error condion is not
acve anymore.
The r
estart behaviour
aer trouble can be congured. 4Automac
restart aer a fault^ 226
60 Heatsink temperature warning acve TRUE if current heatsink temperature > warning threshold for
temperature monitoring. Otherwise FALSE.
Display of the current heatsink temperature in 0x2D84:001 (P117.01).
Seng of the warning threshold in 0x2D84:002.
66 Flying restart circuit acve TRUE if ying restart circuit acve is acve. Otherwise FALSE.
4Flying restart circuit^ 154
67 DC braking acve TRUE if DC braking is acve. Otherwise FALSE.
4DC br
aking^ 158
68 Stop command acve TRUE if delay to standsll acve. Otherwise FALSE.
69 Rotaonal
direcon reversed TRUE if output frequency is negave. Otherwise FALSE.
70 Frequency threshold exceeded TRUE if current output frequency > frequency threshold. Otherwise
FALSE.
Display of the current output frequency in 0x2DDD (P100.00).
Seng Frequency threshold in 0x4005 (P412.00).
4Trigger acon if a frequency threshold is exceeded^ 242
71 Actual speed = 0
TRUE if current output frequency = 0 Hz (± 0.01 Hz),
irrespecve of the
operang mode. Otherwise FALSE.
Display of the current output frequency in 0x2DDD (P100.00).
72 Setpoint speed reached TRUE if frequency setpoint reached. Otherwise FALSE.
73 PID feedback = setpoint TRUE if the controlled feedback variable = process controller setpoint (±
in 0x404D:003
(P608.03) set hysteresis). Otherwise FALSE.
4Conguring the process controller^ 98
74 PID sleep mode acve TRUE if the inverter is in "PID sleep mode". Otherwise FALSE.
4Pr
ocess controller sleep mode^ 105
75 PID MIN alarm acve TRUE if feedback variable (with acvated PID control) < MIN alarm
thr
eshold. Otherwise FALSE.
Seng of MIN alarm threshold in 0x404D:001 (P608.01).
4
Conguring the process controller^ 98
76 PID MAX alarm acve TRUE if the feedback variable (with acvated PID control) > MAX alarm
threshold. Otherwise FALSE.
Seng of MAX alarm threshold in 0x404D:002 (P608.02).
4
Conguring the process controller^ 98
77 PID MIN-MAX alarm acve TRUE if no PID alarm is acve with acvated PID control (MIN alarm
threshold < feedback variable < MAX alarm threshold). Otherwise FALSE.
Seng of MIN alarm threshold in 0x404D:001 (P608.01).
Seng of MAX alarm threshold in 0x404D:002 (P608.02).
4
Conguring the process controller^ 98
78 Current limit reached
TRUE if current motor current ma
ximum current. Otherwise FALSE.
Display of the present motor current in 0x2D88 (P104.00).
Seng for the maximum current in 0x6073 (P324.00).
I/O extensions and control connecons
Congure digital outputs
R
elay output
212