EasyManua.ls Logo

Lenze i410 - Error Codes, Causes and Remedies

Lenze i410
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14.6 Error codes, causes and remedies
The following table contains the most important error codes of the device in ascending order.
Clicking the err
or code shows you a detailed descripon of the error message.
If the de
vice displays an "internal error" that is not listed here, restart the device. If the
error persists, make a note of the error code and contact the manufacturer.
Error code Error message Error type Congurable in
8784 0x2250 CiA:
Connuous over current (internal) Fault -
8992 0x2320 CiA: Short circuit/earth leakage (internal) Fault -
9024 0x2340 CiA: Short circuit (device internal) Fault -
9040 0x2350 CiA: i²*t overload (thermal state) Fault 0x2D4B:003 (P308.03)
9090 0x2382 I*t error Fault 0x2D40:005 (P135.05)
9091 0x2383 I*t warning Warning -
9095 0x2387 Imax: Clamp responded too oen Fault -
9096 0x2388 SL-PSM stall detecon acve Trouble -
9098 0x238A Maximum current reached Informaon -
12576 0x3120 Mains phase fault Fault -
12672 0x3180 UPS operaon acve Warning -
12816 0x3210 DC bus overvoltage Fault -
12817 0x3211 DC bus overvoltage warning Warning -
12832 0x3220 DC bus undervoltage Trouble -
12833 0x3221 DC bus undervoltage warning Warning -
12834 0x3222 DC-bus voltage to low for power up Warning -
16912 0x4210 PU: overtemperature fault Fault -
17024 0x4280 Heat sink temperature sensor fault Fault -
17025 0x4281 Heat sink fan warning Warning -
17029 0x4285 PU overtemperature warning Warning -
20754 0x5112 24 V supply crical Warning -
20864 0x5180 Overload 24 V supply Warning -
21376 0x5380 OEM hardware incompable Fault -
24970 0x618A Internal fan warning Warning -
25216 0x6280 Trigger/funcons connected incorrectly Trouble -
25217 0x6281 User-dened fault 1 Fault -
25218 0x6282 User-dened fault 2 Fault -
25232 0x6290 Warning invert
rotaon Warning -
25233 0x6291 Maximuml allowed troubles exceeded Fault -
25248 0x62A0 User-dened fault (LECOM) Fault -
25249 0x62A1 Network: user fault 1 Fault -
25250 0x62A2 Network: user fault 2 Fault -
25265 0x62B1 NetWordIN1 conguraon incorrect Trouble -
25505 0x63A1 CU: load error ID tag Fault -
25506 0x63A2 PU: load error ID tag Fault -
25507 0x63A3 Power unit unknown Fault -
28800 0x7080 Asseron level monitoring (Low/High) Fault -
28801 0x7081 Analog input 1 fault Fault 0x2636:010 (P430.10)
28802 0x7082 Analog input 2 fault Fault 0x2637:010 (P431.10)
28833 0x70A1 Analog output 1 fault Warning -
28834 0x70A2 Analog output 2 fault Warning -
28961 0x7121 Pole
posion idencaon fault Fault 0x2C60
29056 0x7180 Motor overcurrent Fault 0x2D46:002 (P353.02)
30336 0x7680 Memory module is full Warning -
30337 0x7681 Memory module not present Fault -
30338 0x7682 Memory module: Invalid user data Fault -
30340 0x7684 Data not compl. saved before powerdown Warning -
30342 0x7686 Internal communicaon error Fault -
30345 0x7689 Memory module: invalid OEM data Warning -