EasyManua.ls Logo

Lenze i410 - Example: Output Voltage 0

Lenze i410
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
Address Name / seng range / [default seng] Informaon
0x2639:001
(P440.01)
Analog output 1: Output range
(Analog output 1: A
O1 outp. range)
Denion of the output range.
0 Inhibited
1 0 ... 10 VDC
2 0 ... 5 VDC
3 2 ... 10 VDC
4 4 ... 20 mA
5 0 ... 20 mA
0x2639:002
(P440.02)
Analog output 1: Funcon
(Analog output 1: AO1 funcon)
Selecon of the signal to be shown at analog output 1.
0 Not acve No output signal.
1 Output frequency Actual output frequency (resoluon: 0.1 Hz).
2 Frequency setpoint Current frequency setpoint (resoluon: 0.1 Hz).
3 Analog input 1 Input signal of analog input 1 (resoluon: 0.1 %).
4 Analog input 2 Input signal of analog input 2 (resoluon: 0.1 %).
5 Motor current Actual motor current (resoluon: 0.1 A).
6 Output power Actual output power (resoluon: 0.001 kW).
7 Torque actual value (from version 03.00) Current torque (resoluon: 0.1 %).
100 % = permissible maximum torque 0x6072 (P326.00)
11 DC-bus voltage Display of the current DC-bus voltage.
12 Device ulisaon (i*t)
20 NetWordIN3 Actual value of the NetWordIN3 data word (resoluon: 0.1 %).
21 NetWordIN4 Actual value of the NetWordIN4 data word (resoluon: 0.1 %).
0x2639:003
(P440.03)
Analog output 1: Min. signal
(Analog output 1: AO1 min. signal)
-2147483648 ... [0] ... 2147483647
Denion of the signal value that corresponds to the minimum value at
analog output 1.
Example: conguraon of analog output 1 as a 4 ... 20 mA current loop:
output current 4 mA = 0x2639:003
0x2639:004
(P440.04)
Analog output 1: Max. signal
(Analog output 1: AO1 max. signal)
-2147483648 ... [1000] ... 2147483647
Denion of the signal value that corresponds to the maximum value at
analog output 1.
Example: conguraon of analog output 1 as a 4 ... 20 mA current loop:
output current 20 mA = 0x2639:004
10.4.1.1 Example: Output voltage 0 ... 10 V = output frequency 0 ... 100 Hz
In this conguraon, a voltage is provided at the analog output proporonately to the actual
output fr
equency of the inverter (1 V = 10 Hz, resoluon 0.1 Hz).
Parameter Name Seng for this example
0x2639:001 (P440.01) Analog output 1: Output range 0 ... 10 VDC [1]
0x2639:002 (P440.02) Analog output 1: Funcon Output frequency [1]
0x2639:003 (P440.03) Analog output 1: Min. signal 0
0x2639:004 (P440.04) Analog output 1: Max. signal 1000
1000
0
10
[V]
[0.1 Hz]0
100.0
[Hz]
1
100
10.0
AO1
X3
V
0x2639:002
Min
Max
Output frequency [1]
I/O extensions and control connecons
Congure analog outputs
Analog output 1