9.3.3.2 "Automac" brake mode (automac operaon)
In
automac operaon, the inverter automacally released the holding brake when the motor
is started. In the stopped state, the holding brake is closed.
DANGER!
Manual release of the holding brake
In
automac operaon, a manual release of the holding brake is also possible. The manually
triggered "Release holding brake" command has a direct impact on the "Release holding brake
[115]" trigger. Thus, the holding brake can be manually released if the power secon is
switched o.
The responsibility for a manual release of the holding brake has the external trigger source
for the "Release holding brake" command!
General mode of operaon
The following diagram demonstrates the general funconing of the automac operaon:
t
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
t
t
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
t
t
t
t
0x2820:015
0x2820:002
0x2820:003
0x2DDD
Power section switched-on
Output frequency
Active [0]
Brake released [1]
Brake status
Release holding brake [115]
Output signals
Output trigger
Digital input 1 [11] Run
Constant TRUE [1] Enable inverter
Input signals
Frequency setpoint selection
FunctionTrigger
If the inverter is enabled and no error is acve, the motor can be started with the "Run" funcon in forward rotang direcon.
The power secon is switched on and the motor is magnezed
rst.
The holding brake is released. For this purpose, the output trigger "Release holding brake [115]" is set to TRUE. This trigger must be
assigned to a digital output or, in the simplest case, to the relay which then switches the brake supply.
Aer the release me 0x2820:003 (P712.03) has elapsed, the motor is accelerated to the setpoint.
The brake status "Brake released [1]" is displayed in 0x2820:015 (P712.15).
If "Run" is set to FALSE, the motor is stopped with the stop method set in 0x2838:003 (P203.03). In the example: Stop with standard ramp.
Then the holding brake is closed again.
Aer the closing me 0x2820:002 (P712.02) has elapsed, the brake status "Acve [0]" is displayed in 0x2820:015 (P712.15).
If the power
secon is disabled, the holding brake is closed. Reasons for this can
be a fault or trouble.
Conguring the motor control