Address Name / seng range / [default seng] Informaon
0x2DDF:001 Axis informaon: Rated current
•
R
ead only: x.xx A
Display of the rated current of the axis.
0x2DDF:002 Axis informaon: Maximum current
•
Read only: x.xx A
Display of the maximum current of the axis.
0x400D
(P101.00)
Scaled actual value
(Scaled act value)
•
Read only: x Units
Display of the current speed in applicaon units.
0x6077
(P107.00)
Torque actual value
(Torque actual)
•
Read only: x.x %
Display of the current torque.
•
100 % = Ra
ted Motor Torque. 40x6076 (P325.00)
0x6078
(P103.00)
Current actual value
(Current actual)
•
Read only: x.x %
Display of the current motor current.
•
100 % = Motor rated current 0x6075 (P323.00)
0x6079 DC link circuit voltage
•
Read only: x.xxx V
•
From version 02.00
Display of the current DC-bus voltage.
14.4.1 Inverter diagnoscs
The following parameters supply some informaon about the current operang status of the
in
verter.
This includes the following informaon:
•
Curr
ently loaded parameter sengs
•
Cause(s) for disable, quick stop and stop
•
Acve control source and acve setpoint source
•
Acve
operang mode
•
Status of the internal motor control
•
Keypad status
Some of the following parameters contain bit-coded status words. Each single bit has a certain
meaning.
4Display of status words on keypad^ 251
Parameter
Address Name / seng range / [default seng] Informaon
0x2827
(P198.00)
Currently loaded parameter
sengs
(Status load. par)
•
Read only
Display of the parameter sengs currently loaded.
4Saving/loading the parameter sengs ^ 221
0 User sengs User parameter sengs of the memory module
1 Reset 60 Hz seng Delivery status (default seng) for 50-Hz device
2 Reset 50 Hz seng Delivery status (default seng) for 60-Hz device
3 OEM default sengs OEM parameter sengs of the memory module
Diagnoscs and fault eliminaon
Diagnosc parameters
In
verter diagnoscs
274