4.4 General
informaon on parameter seng
As a part of a machine with a speed-variable drive system, the inverter must be adapted to its
drive task. The adaptaon process of the inverter is carried out by changing parameters.
These parameters can be accessed by means of the keypad or »EASY Starter«. If the inverter is
provided with a network opon, access can also be eected by a higher-level controller via
the corresponding network.
Certain device commands or sengs which might cause a crical state of the
driv
e behavior can only be carried out when the device is disabled.
4.4.1 Addressing of the parameters
Each parameter features a 16-bit index as its address. Under this address, the parameter is
s
tored in the object directory of the device.
P
arameters that belong together funconally are combined in a data set. These
par
ameters are addionally provided with an 8-bit subindex.
The colon is used as a separator between the index and subindex Example: "0x2540:001"
There are parameter sengs that can be changed, and (diagnosc) parameters that can
only be read.
Parameterisaon using the keypad
All par
ameters which can also be accessed by means of the keypad have a "Display code",
with the rst digit of the display code specifying the group in which the parameter can be
f
ound on the keypad.
In the documentaon, the display code is specied in brackets behind the address.
Example: "0x2915 (P210.00)".
Commissioning
Gener
al informaon on parameter seng
Addressing of the parameters
22