Address Name / seng range / [default seng] Informaon
0x2631:011
(P400.11)
Funcon list: Jog reverse (CCW)
(Funcon list: Jog reverse)
Seng can only be changed if the inverter is
disabled.
F
or further possible sengs, see parameter
0x2631:010 (P400.10). ^ 50
Assignment of a trigger for the "Jog reverse (CCW)" funcon.
Trigger = TRUE: Let motor rotate backward with preset 6.
Trigger = FALSE: Stop motor.
CAUTION! The jog operaon has a higher priority than the "Run"
funcon, all other start commands and the keypad key .
If jog operaon is acve, the motor cannot be stopped with the
pr
eviously menoned funcons!
Ho
wever, jog operaon can be interrupted by the "Quick stop"
funcon.
Notes:
The pr
eset 6 can be set in 0x2911:006 (P450.06).
The stop method can be selected in 0x2838:003 (P203.03).
If "Jog foward (CW)" and "Jog reverse (CCW)" are acvated at the
same me, the motor is stopped using the set stop method and jog
operaon must be triggered again.
Jog operaon cannot be started automacally. The "Start at power-
up" opon in 0x2838:002 (P203.02) does not apply to jog operaon.
4Ex
ample: Jog forward/Jog reverse^ 57
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:013
(P400.13)
Funcon list: Reverse rotaonal direcon
(Funcon list: Reverse rot.dir.)
Seng can only be changed if the inverter is
disabled.
Further possible sengs: 4T
rigger list ^ 52
Assignment of a trigger for the "Reverse rotaonal direcon"
funcon.
Trigger = TRUE: the setpoint specied is inverted (i. e. the sign is
inverted).
Trigger = FALSE: no acon / deacvate funcon again.
4Example: Start/stop (1 signal) and reversal^ 54
13 Digital input 3 State of X3/DI3, taking an inversion set in 0x2632:003
(P411.03) into
consideraon.
6.2.1 Trigger list
The trigger list lists all selecon opons (triggers) for the funcons which can be congured
using the parameters 0x2631:xx (P400.xx).
Selecon Informaon
0 Not connected No trigger assigned (trigger is constantly FALSE).
1 Constant TRUE Trigger is constantly TRUE.
11 Digital input 1 State of X3/DI1, taking an inversion set in 0x2632:001
(P411.01) into
consideraon.
12 Digital input 2 State of X3/DI2, taking an inversion set in 0x2632:002 (P411.02) into
consideraon.
13 Digital input 3 State of X3/DI3, taking an inversion set in 0x2632:003 (P411.03) into
consideraon.
14 Digital input 4 State of X3/DI4, taking an inversion set in 0x2632:004 (P411.04) into
consideraon.
15 Digital input 5 State of X3/DI5, taking an inversion set in 0x2632:005 (P411.05) into
consideraon.
50 Running TRUE if inverter and start are enabled and output frequency > 0 Hz.
Otherwise FALSE.
Excepon, quick stop mode: TRUE if inverter and start are enabled and
output frequency > 0.2 Hz. Otherwise FALSE.
51 Ready for operaon TRUE if inverter is ready for operaon (no error acve, no STO acve and
DC-bus voltage ok). Otherwise FALSE.
TRUE, wenn Inverter betriebsbereit (kein Fehler akv und
Zwischenkreisspannung ok). Sonst FALSE.
53 Stop acve TRUE if inverter is enabled and motor is not started and output
fr
equency = 0.
54 Quick stop acve TRUE if quick stop is acve. Otherwise FALSE.
58 Device warning acve TRUE if warning is acve. Otherwise FALSE.
A w
arning has no impact on the operang status of the inverter.
A warning is reset automacally if the cause has been eliminated.
Start, stop and rotang
direcon commands
Flexible I/O conguraon of the start, stop and rotang direcon commands
Trigger list
52