5.7 Motor data
The term "motor data" comprises all parameters only depending on the motor and only
char
acterising the electrical behaviour of the motor. Motor data are independent of the
applicaon in which the inverter and the motor are used.
Precondions
The equivalent circuit data ("Sengs" tab, path: "Basic seng\motor", parameterisaon
dialog "Derived motor properes and equivalent circuit") apply to a motor in star connecon.
In case of a motor in delta connecon, the delta values must be converted into equivalent star
values.
Possible sengs
If a Lenze motor is connected to the inverter, you can select the motor in the engineering tool
from the "motor catalogue".
•
For details see chapter "Select motor from motor catalog". ^ 40
Otherwise the motor data must be set manually (for details see chapter "Manual seng of
the motor data“). ^ 41
Basic seng
Motor data
39