5.7.1 Select motor from motor catalog
The following describes how to parameterise your drive system by selecng a Lenze motor
fr
om the motor catalogue. Several processes are started invisibly in the background to load/
calculate the sengs for the relevant parameters.
Precondions
•
Access t
o a Lenze engineering tool (e. g. »EASY Starter«).
•
Parameters can be set online or
oine (with or without connected motor).
Required steps
1.Open the Lenze engineering tool that provides for the funconality of a “Motor Catalog".
2.Click the Select motor... buon. In case of the »EASY Starter«, you nd the Select motor...
buon on the "sengs". tab.
3.Select the motor used in the "Select motor" dialog:
By entering lter criteria, you can restrict the selecon.
Name (e. g. "MCS..."), rated power and C86 value can be found on the motor
nameplate.
Observe the notes on the ?
buon.
4.Click the OK
buon to start the opmizaon.
Parameterizaon sequence
As soon as the parameterizaon has been started, the following steps are iniated by the
engineering tool:
1.The motor rang data and the motor equivalent circuit diagram data are loaded from the
motor catalog.
2.The motor controller sengs and the speed controller sengs are automacally calculated
based on the previously loaded data.
Notes:
•
The data involved in this parameterizaon are provided by the motor catalog alone.
Further user data is not required.
•
The inverter characteriscs are not changed by this opmizaon.
Basic
seng
Motor data
Select motor from motor catalog
40