16 Appendix
16.1
Parameter aribute list
The parameter aribute list in parcular contains some informaon required for reading and
wring parameters via network.
The par
ameter aribute list contains all parameters of the inverter.
The par
ameter aribute list is sorted by addresses (index:subindex) in ascending order.
How to read the parameter aribute list:
Column Meaning
Address Address of the parameter in the object directory. Format: index:subindex
If the par
ameter can also be accessed via keypad, the "Display Code" is given in addion in brackets.
Name Parameter name
Default seng Default seng of the parameter
Category Funconal assignment of the parameter, for example "motor control" or "CANopen".
Data type Data type of the parameter:
I8 1 byte, with sign
I16 2 bytes with sign
I32 4 bytes with sign
I64 8 bytes with sign
U8 1 byte without sign
U16 2 bytes without sign
U32 4 bytes without sign
U64 8 bytes without sign
REAL32 4 bytes oang point
STRING[xx] ASCII string (with character length xx)
OCTET[xx] OCTET string (with xx bytes)
IDX 4 bytes without sign. Is used specially for addressing parameters.
Factor Factor for data transmission via network, depending on the number of decimal posions:
1 No decimal posions
10 1 decimal posion
100 2 decimal posions
1000 3 decimal posions
10000 4 decimal posions
A Aributes (combinaons of several
aributes also possible):
C Seng can only be changed if the inverter is inhibited.
E Value is displayed as IP address on the keypad.
H Value is displayed as hexadecimal value on the keypad.
I Parameter is not displayed.
k Parameter is only displayed on the keypad.
O Parameter can be recorded with the oscilloscope funcon.
P Seng is saved in the memory module.
X Parameter is not displayed in the engineering tools.
M Mapping:
r Receive mapping permissible.
t Transmit mapping permissible.
rt Receive and transmit mapping permissible.
- Mapping not permissible.
Parameter aribute list (short overview of all parameter indexes)
Address Name Default seng Category Data type Factor A M
0x2000:001
(P190.01)
Device data: Product code - (Read only) general STRING[18] 1 - -
0x2000:002
(P190.02)
Device data: Serial number - (Read only) general STRING[50] 1 - -
* Default seng dependent on the model.