Inversion
Each digital input can be congured in such a way that the status pending at the terminal is
logic
ally inverted internally. This way, a closed contact, for instance, serves to deacvate an
assigned funcon instead of acvang it. Thus, the control of the inverter can be exibly
adapted to the requirements of the actual applicaon.
Parameter
Address Name / seng range / [default seng] Informaon
0x2630:002
(P410.02)
Sengs for digital inputs: Input funcon
(DI
sengs: Input funcon)
Input funcon of the digital terminals DI3 and DI4.
0 Digital input DI3 = digital input
DI4 = digital input
0x2632:001
(P411.01)
Inversion of digital inputs: Digital input 1
(DI inversion: DI1 inversion)
Inversion of digital input 1
0 Not inverted
1 Inverted
0x2632:002
(P411.02)
Inversion of digital inputs: Digital input 2
(DI inversion: DI2 inversion)
Inversion of digital input 2
0 Not inverted
1 Inverted
0x2632:003
(P411.03)
Inversion of digital inputs: Digital input 3
(DI inversion: DI3 inversion)
Inversion of digital input 3
0 Not inverted
1 Inverted
0x2632:004
(P411.04)
Inversion of digital inputs: Digital input 4
(DI inversion: DI4 inversion)
Inversion of digital input 4
0 Not inverted
1 Inverted
0x2632:005
(P411.05)
Inversion of digital inputs: Digital input 5
(DI inversion: DI5 inversion)
Inversion of digital input 5
0 Not inverted
1 Inverted
0x2633:001 Digital input debounce me: Digital input 1
1 ... [1] ... 50
ms
Debounce me of digital input 1
0x2633:002 Digital input debounce me: Digital input 2
1 ... [1] ... 50 ms
Debounce me of digital input 2
0x2633:003 Digital input debounce me: Digital input 3
1 ... [1] ... 50 ms
Debounce me of digital input 3
0x2633:004 Digital input debounce me: Digital input 4
1 ... [1] ... 50 ms
Debounce me of digital input 4
0x2633:005 Digital input debounce me: Digital input 5
1 ... [1] ... 50 ms
Debounce me of digital input 5
Example:
Acvang two funcons simultaneously via digital input 4
The principle of assigning triggers to funcons also enables a digital input to be assigned to
several funcons. The wiring complexity is reduced since there is no necessity to interconnect
several digital inputs.
If, for instance, the frequency preset 1 is to be selected via the digital input 4 and a change-
over to the acceleraon me 2 and deceleraon me 2 is to take place at the same me, this
can be easily realised by the following parameter seng:
Parameter Designaon Seng for this example
0x2631:018 (P400.18) Acvate preset (bit 0) Digital input 4 [14]
0x2631:039 (P400.39) Acvate ramp 2 Digital input 4 [14]
In order to achieve the desired behaviour, the digital input 4 must not be
assigned t
o any further funcons!
I/O extensions and control connecons
Congure digital inputs
204