8992 0x2320 CiA: Short circuit/earth leakage (internal) Keypad display: E
arth leak
Cause Remedy Error type/response
Short cir
cuit/earth fault of motor cable
Capacive charging current of the motor
c
able too high.
Check mot
or cable.
Check length of the motor cable.
Use shorter or lower-capacitance motor
cable.
Fault
The in
verter is disabled immediately. The
motor has no torque (coasts).
The error can only be reset aer a blocking
me.
Blocking me: 5 s
9024 0x2340 CiA: Short circuit (device internal) Keypad display: Mot
or shorted
Cause Remedy Error type/response
Short circuit of motor cable Check motor cable for short circuit. Fault
The in
verter is disabled immediately. The
motor has no torque (coasts).
The error can only be reset aer a blocking
me.
Blocking me: 5 s
9040 0x2350 CiA: i²*t overload (thermal state) Keypad display: i2t mot
or
Cause Remedy Error type/response
Motor thermally overloaded, e. g. by an
impermissible connuous current or by
fr
equent or too long acceleraon processes.
Check driv
e sizing.
Check machine/driven mechanics for
excessive load.
Check
sengs of the motor data.
Reduce values for slip compensaon
0x2B09:001 (P315.01), 0x2B09:002 (P315.02)
and oscillaon damping 0x2B0A:001
(P318.01), 0x2B0A:002 (P318.02).
Fault (congurable)
The err
or can only be reset aer a blocking
me.
Blocking me: 5 s
Seng parameters: 0x2D4B:003
(P308.03)
Related topics
4Mot
or overload monitoring (i²*t) ^ 190
9090 0x2382 I*t error Keypad display: Ixt err
or
Cause Remedy Error type/response
Device
ulisaon (I*t) too high by frequent and
too long acceleraon processes.
Check drive sizing.
Reduce the maximum overload current of
the inverter 0x6073 (P324.00).
In case of high mass ineras, reduce
maximum overload current of the inverter
0x6073 (P324.00) to 150 %.
Fault (congurable)
The err
or can only be reset aer a blocking
me.
Blocking me: 3 s
Seng parameters: 0x2D40:005
(P135.05)
Related topics
4De
vice overload monitoring (i*t) ^ 225
9091 0x2383 I*t warning Keypad display: Ixt w
arning
Cause Remedy Error type/response
Device
ulisaon (I*t) too high by frequent and
too long acceleraon processes.
Check drive dimensioning. Warning
Related topics
4De
vice overload monitoring (i*t) ^ 225
Diagnoscs and fault eliminaon