30340 0x7684 Data not compl. saved before powerdown Keypad display: Sa
ve incomplete
Cause Remedy Error type/response
Saving of the parameter sengs was
in
terrupted by an unexpected disconnecon.
1.
Check user par
ameter sengs. (The loaded
back
up is an older version.)
2.
If required, repeat the changes made last.
3.
Execute device command "Save user data"
0x2022:003 (P700.03).
Warning
•
The user par
ameter sengs were not fully
saved.
•
At the next switch-on, the data stored are
copied to the user memory.
30342 0x7686 Internal communicaon error Keypad display: In
t. Comm.Err.
Cause Remedy Error type/response
Fault
30345 0x7689 Memory module: invalid OEM data Keypad display: OEM da
ta invalid
Cause Remedy Error type/response
The OEM memory contains invalid parameter
sengs or is empty.
•
Execute device command "Save OEM data"
0x2022:006 (P700.06).
•
Thus, the user parameter sengs get lost!
Warning
•
The user par
ameter sengs were
automacally loaded.
30346 0x768A Memory module: wrong type Keypad display: W
rong EPM
Cause Remedy Error type/response
Error message is not available for the inverter
i410.
Fault
30352 0x7690 EPM
rmware version incompable Keypad display: EPM-FW incomp.
Cause Remedy Error type/response
The parameter sengs saved in the memory
module ar
e incompable with the rmware
version.
1.
Ex
ecute device command "Load default
sengs" 0x2022:001
(P700.01).
2.
Execute "Save user data" 0x2022:003
(P700.03) or "Save OEM data" 0x2022:006
(P700.06) device command.
Fault
•
The data have been loaded into the RAM
memory, but they are incompable.
30353 0x7691 EPM data: rmware type
incompable Keypad display: EPM: FW incomp.
Cause Remedy Error type/response
The parameter sengs saved in the memory
module ar
e incompable with the rmware
type.
Example: Memory module of an inverter with
an applicaon IO is used in an inverter with a
standard IO.
1.
Ex
ecute device command "Load default
sengs" 0x2022:001
(P700.01).
2.
Execute "Save user data" 0x2022:003
(P700.03) or "Save OEM data" 0x2022:006
(P700.06) device command.
Fault
•
The data have been loaded into the RAM
memory, but they are incompable.
30354 0x7692 EPM data: new rmware type detected Keypad display: UserCU not ma
tch
Cause Remedy Error type/response
The parameter sengs saved in the memory
module do not ma
tch the inverter hardware.
1.
Check par
ameter sengs.
2.
R
eset error.
3.
Execute "Save user data" 0x2022:003
(P700.03) or "Save OEM data" 0x2022:006
(P700.06) device command.
Fault
•
The da
ta have been loaded into the RAM
memory without being modied, and they
are compable.
•
The sengs loaded must be accepted by the
user (see remedy).
Diagnoscs and fault eliminaon
Error codes, causes and remedies
300