30355 0x7693 EPM data: PU size
incompable Keypad display: EPM PU size inco
Cause Remedy Error type/response
The parameter sengs saved in the memory
module ar
e incompable with the inverter.
1.
Ex
ecute device command "Load default
sengs" 0x2022:001
(P700.01).
2.
Execute "Save user data" 0x2022:003
(P700.03) or "Save OEM data" 0x2022:006
(P700.06) device command.
Fault
•
The data have been loaded into the RAM
memory, but they are incompable.
30356 0x7694 EPM data: new PU size detected Keypad display: EPM ne
w PU size
Cause Remedy Error type/response
The parameter sengs saved in the memory
module c
omply with a dierent hardware.
Example: Memory module of an inverter with a
power of 3 kW is used in an inverter with a
power of 18.5 kW.
1.
Check par
ameter sengs.
2.
R
eset error.
3.
Execute "Save user data" 0x2022:003
(P700.03) or "Save OEM data" 0x2022:006
(P700.06) device command.
Fault
•
The da
ta have been loaded into the RAM
memory without being modied, and they
are compable.
•
The sengs loaded must be accepted by the
user (see remedy).
30357 0x7695 Invalid parameter changeover
conguraon Keypad display: InvalidChgovrCfg
Cause Remedy Error type/response
One or more parameters can no longer be used
f
or the "Parameter change-over" funcon.
1.
Check err
or message for parameter change-
over in 0x4047:001 (P756.01).
2.
Correct the list entry shown in 0x4047:002
(P756.02).
Warning
•
The par
ameter change-over funcon is
deacvated.
30358 0x7696 EPM data: unknown parameter found Keypad display: Unkn. P
ar in EPM
Cause Remedy Error type/response
The memory module contains parameter
sengs for one or several parameters that are
not kno
wn to the inverter.
Execute the "Save user data" 0x2022:003
(P700.03) device command. This reinialises
the user memory with the current parameter
sengs. In this way, parameter sengs that are
no longer required are automacally deleted.
Informaon
30359 0x7697 Parameter changes lost Keypad display: P
arameter loss
Cause Remedy Error type/response
A voltage failure has occurred and changed
par
ameter sengs that had not been saved yet
were available.
1.
Ex
ecute parameter sengs again.
2.
Ex
ecute device command "Save user data"
0x2022:003 (P700.03).
Fault
•
The parameter sengs changed have been
lost.
33045 0x8115 Time-out (PAM) Keypad display: Time-out (P
AM)
Cause Remedy Error type/response
Error message is not available for the inverter
i410.
No response
(congurable)
Seng parameters: 0x2552:004
33050 0x811A BACnet me-out Keypad display: B
ACnet me-out
Cause Remedy Error type/response
Error message is not available for the inverter
i410.
Fault (congurable)
Seng parameters: 0x2856:001
Diagnoscs and fault eliminaon
Error codes, causes and remedies
301