Address Name / seng range / [default seng] Informaon
79 Torque limit reached TRUE if torque limit has been reached or exceeded. Otherwise FALSE.
Seng "Actual posive torque limit" in 0x2949:003
(P337.03).
Seng Actual negave torque limit in 0x2949:004 (P337.04).
Motor torque monitoring ^ 197
81 Error of analog input 1 acve TRUE if the monitoring of the input signal at the analog input 1 has
responded. Otherwise FALSE.
This trigger is set as a funcon of the following sengs:
Monit
oring threshold0x2636:008 (P430.08)
Monitoring condion0x2636:009 (P430.09)
The
seng of the Error response in 0x2636:010 (P430.10) has no eect
on this trigger.
4Analog input 1^ 205
82 Error of analog input 2 acve TRUE if the monitoring of the input signal at the analog input 2 has
r
esponded. Otherwise FALSE.
This trigger is set as a funcon of the following sengs:
Monit
oring threshold0x2637:008 (P431.08)
Monitoring condion0x2637:009 (P431.09)
The
seng of the Error response in 0x2637:010 (P431.10) has no eect
on this trigger.
4Analog input 2^ 209
83 Load loss detected TRUE if actual motor current < threshold for load loss detecon
aer
delay me of the load loss detecon has elapsed. Otherwise FALSE.
Display of the present motor current in 0x6078 (P103.00).
Seng Threshold in 0x4006:001 (P710.01).
Seng Delay me in 0x4006:002 (P710.02).
4Load loss detecon^ 174
84 Heavy load monitoring TRUE if the actual apparent current of the motor exceeds the threshold
f
or longer than the delay me. FALSE if the actual apparent current of
the motor falls below the threshold value minus 5% (hysteresis) Heavy
load monitoring ^ 201 .
104 Local control acve TRUE if local keypad control ("LOC") acve. Otherwise FALSE.
105 Remote control
acve TRUE if remote control ("REM") via terminals, network, etc. acve.
Otherwise FALSE.
106 Manual setpoint selecon acve TRUE if manual setpoint selecon ("MAN") via keypad acve. Otherwise
FALSE.
Selecon of the trigger for the "Acvate keypad setpoint" funcon in
0x2631:016 (P400.16).
107 Automac setpoint selecon acve TRUE if automac setpoint selecon ("AUTO") via terminals, network,
etc. acve. Otherwise FALSE.
108 Parameter set 1 acve TRUE if parameter set 1 is loaded and acve. Otherwise FALSE.
109 Parameter set 2 acve TRUE if parameter set 2 is loaded and acve. Otherwise FALSE.
110 Parameter set 3 acve TRUE if parameter set 3 is loaded and acve. Otherwise FALSE.
111 Parameter set 4 acve TRUE if parameter set 4 is loaded and acve. Otherwise FALSE.
112 Parameter set load OK TRUE aer any parameter set has been loaded. Otherwise FALSE.
113 Parameter set load fail TRUE if any of the parameter sets could not be loaded. Otherwise FALSE.
115 Release holding brake Trigger signal for releasing the holding brake (TRUE = release holding
br
ake).
Note!
If this trigger is assigned to the relay or a digital output, the deceleraon
mes set for the respecve output are not eecve (are internally set to
"0"). Only the deceleraon me set in 0x2820:012 (P712.12) for closing
the holding brake inuences in this case the me-dependent behaviour
of the output.
4Holding brake control^ 165
117 Motor phase failure TRUE if a motor phase failure has been detected. Otherwise FALSE.
4Mot
or phase failure detecon ^ 195
118 UPS operaon
acve Funcon is not supported in this device.
TRUE if UPS operaon is acve. Otherwise FALSE.
I/O extensions and control connecons
Congure digital outputs
R
elay output
213