Commissioning
For commissioning the sequencer, we recommend the following proceeding:
1.
Congure segments (including end segment).
De
tails: 4Segment conguraon ^ 75
2.
Congure sequences:
a)
Assign the segments to the single steps of a sequence.
b)
Set the number of cycles for the respecve sequence.
De
tails: 4Sequence conguraon ^ 85
3.
Mak
e the basic seng of the sequencer:
a)
Set the desired operang mode (me and/or step operaon).
b)
Oponally adjust the sequence end mode and the sequence start mode.
De
tails: 4Sequencer basic sengs ^ 89
4.
Congure the control of the sequencer:
a)
Assign the funcons for selecng a sequence to suitable triggers (e. g. digital inputs).
b)
Assign the funcons for controlling the sequencer (start, stop, cancel, ...) to suitable
trig
gers.
Details: 4Sequencer control funcons ^ 92
Control
The sequencer can be controlled with the following funcon. For details, see chapter
"Sequencer control funcons". ^ 92
Funcon Informaon
Select sequence (bit 0) ... Select
sequence (bit 3)
Bit coded selecon of the sequence to be started.
Start sequence The selected sequence is started. The start can take place edge or status-controlled depending on the
conguraon.
Next sequence step Immediate jump to the next step irrespecve of the
me set for the segment.
Pause sequence The sequencer stops in the current step. The elapsing me set for the segment is stopped. The sequencer
setpoint remains acve.
Suspend sequence There is a temporary return to the normal setpoint control. The sequence is then connued at the point
where it was suspended.
Stop sequence Direct jump to the end segment. The further execuon depends on the selected end of sequence mode.
Abort sequence Immediate return to the normal setpoint control. The end segment is not executed anymore.
Diagnoscs
For diagnosing the sequencer, the diagnosc parameters listed in chapter "Sequencer
diagnoscs" are available. ^ 96
Internal status signals
The sequencer provides dierent internal status signals (see the following table). These status
signals c
an be assigned to the relay, the digital outputs or the status word NetWordOUT1.
4Congure digital outputs ^ 211
Internal status signal Informaon
"Sequencer controlled [100]" The control is executed via the sequencer (according to the conguraon of the digital outputs for the current
segmen
t).
"Sequence acve [101]" The sequence is running and is currently not suspended.
"Sequence suspended [102]" The sequence is currently suspended.
"Sequence done [103]" The sequence is completed (end segment was passed through).
Conguring the frequency control
Congure setpoint sources
Sequencer