Address Name / seng range / [default seng] Informaon
0x2DAE:003
(P140.03)
Sequencer
diagnoscs: Step me remaining
(Sequencer diag: StepTime remain)
Read only: x.x s
From version 03.00
Display of the remaining me for the current step.
0x2DAE:004
(P140.04)
Sequencer diagnoscs: Steps complete
(Sequencer diag: Steps complete)
Read only
From version 03.00
Display of the number of steps that have been made since the start of
the sequence.
0x2DAE:005
(P140.05)
Sequencer diagnoscs: Steps remaining
(Sequencer diag: St
eps remain)
Read only
From version 03.00
Display of the remaining number of steps unl the current sequence is
completed. This includes the current step.
0x2DAE:006
(P140.06)
Sequencer
diagnoscs: Acve sequence
(Sequencer diag: Acve sequence)
Read only
From version 03.00
Display of the acve sequence.
0 = no sequence acve.
0x2DAE:007
(P140.07)
Sequencer diagnoscs: Acve segment
(Sequencer diag: Acve segment)
Read only
From version 03.00
Display of the acve segment.
0 = no sequence acve.
255 = nal sequence acve.
0x2DAE:008
(P140.08)
Sequencer diagnoscs: Relave sequence me
remaining
(Sequencer diag: SeqTime remain %)
Read only: x %
From version 03.00
Display of the remaining me of the sequence in [%].
0x2DAE:009
(P140.09)
Sequencer diagnoscs: Absolute sequence me
remaining
(Sequencer diag: SeqTime remain)
Read only: x.x s
From version 03.00
Display of the remaining me of the sequence in [s].
0x2DAE:010 Sequencer diagnoscs: Frequency setpoint
R
ead only: x.x Hz
From version 03.00
Display of the current frequency setpoint of the "sequencer" funcon.
0x2DAE:011 Sequencer diagnoscs: PID setpoint
Read only: x.xx PID unit
From version 03.00
Display of the current PID control value of the "sequencer" funcon.
0x2DAE:012 Sequencer diagnoscs: Torque setpoint
Read only: x.x %
From version 03.00
Display of the current torque setpoints of the "sequencer" funcon.
100 % = Mot
or rated torque0x6076 (P325.00)
Conguring the frequency control
Congure setpoint sources
Sequencer