EDS94ARNExxxx EN 2.3 - 06/2014 L 307
9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00378
C00378
C00379
C00381
C00382
C00383
Parameter | Name:
C00378 | CAN delay boot-up - Operational
Data type: UNSIGNED_16
Index: 24197
d
= 5E85
h
Time which must elapse after mains switching before the CAN NMT master puts the "Start remote node" telegram
on the bus.
The delay time is only used when the master bit is activated (C00352
) and the device has been restarted.
"CAN on board" system bus
Setting range (min. value | unit | max. value) Lenze setting
0 ms 65535 3000 ms
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00379 | Service code
Data type: UNSIGNED_8
Index: 24196
d
= 5E84
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00381 | CAN Heartbeat Producer Time
Data type: UNSIGNED_16
Index: 24194
d
= 5E82
h
Time interval for sending the heartbeat telegram to the consumer(s).
The parameterised time interval is rounded down to an integer multiple of 5 ms.
The heartbeat telegram is sent automatically if a time interval > 0 ms is set. In this case the "node guarding"
monitoring function is deactivated.
Mapping of the CANopen object I-1017
(see DS301 V4.02).
"CAN on board" system bus: heartbeat protocol
Setting range (min. value | unit | max. value) Lenze setting
0 ms 65535 0ms
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00382 | CAN Guard Time
Data type: UNSIGNED_16
Index: 24193
d
= 5E81
h
After the set guard time multiplied by the life time factor (C00383), a node guarding telegram must have been
received.
Mapping of the CANopen object I-100C
(see DS301 V4.02).
"CAN on board" system bus: node guarding protocol
Setting range (min. value | unit | max. value) Lenze setting
0 ms 65535 0ms
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00383 | CAN Life Time Factor
Data type: UNSIGNED_8
Index: 24192
d
= 5E80
h
The life time factor multiplied by the guard time (C00382) results in the time during which a node guarding
telegram must have been received.
Mapping of the CANopen object I-100D
(see DS301 V4.02).
"CAN on board" system bus: node guarding protocol
Setting range (min. value | unit | max. value) Lenze setting
0 255 0
Read access Write access CINH PLC STOP No transfer