EasyManuals Logo

LSIS S100 User Manual

LSIS S100
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #191 background imageLoading...
Page #191 background image
Table of Functions
179
Code
Comm.
Address
Name LCD Display Setting Range
Initial
Value
Property*
V/F SL Ref.
86
37
0h1456
Flux
estimator
proportion
al gain2
Flux P
Gain2
0-100 0 O X I -
87
37
0h1457
Flux
estimator
proportion
al gain3
Flux P
Gain3
0-500 100 O X I -
88
37
0h1458
Flux
estimator
integral
gain1
Flux I Gain1 0-200 50 O X I -
89
37
0h1459
Flux
estimator
integral
gain2
Flux I Gain2 0-200 50 O X I -
90
37
0h145A
Flux
estimator
integral
gain3
Flux I Gain3 0-200 50 O X I -
91
37
0h145B
Sensorless
voltage
compensat
ion1
SL Volt
Comp1
0-60
Depend
ent on
motor
setting
O X I -
92
37
0h145C
Sensorless
voltage
compensat
ion2
SL Volt
Comp2
0-60 O X I -
93
37
0h145D
Sensorless
voltage
compensat
ion3
SL Volt
Comp3
0-60 O X I -
94
37
0h145E
Sensorless
field
weakening
start
frequency
SL FW Freq 80.0-110.0(%) 100.0 X X I -
95
37
0h145F
Sensorless
gain
switching
frequency
SL Fc Freq 0.00-8.00(Hz) 2.00 X X I -

Table of Contents

Other manuals for LSIS S100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS S100 and is the answer not in the manual?

LSIS S100 Specifications

General IconGeneral
BrandLSIS
ModelS100
CategoryDC Drives
LanguageEnglish

Related product manuals