EasyManua.ls Logo

LSIS S100 - 6.2 Basic Function group (PAR→BAS)

LSIS S100
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
160
Table of Functions
Code
Comm.
Address
Name LCD Display Setting Range
Initial
value
Property*
V/F SL Ref.
9
APP Grp
12
PRT Grp
13
M2 Grp
94 0h115E
Password
registration
-
0-
99
99
O O I/P -
95 0h115F
Parameter lock
settings
-
0-
99
99
O O I/P -
97 0h1161
Software
version
-
O I/P -
98 0h1162
Display I/O
board version
IO S/W Ver
O I/P
99 0h1163
Display I/O
board HW
version
IO H/W Ver
0
Multiple IO
Standard
IO
O I/P -
1
Standard
IO
2
Standard
IO (M)
6.2 Basic Function group (PARBAS)
In the following table, the data shaded in grey will be displayed when a related code has been
selected.
SL: Sensorless vector control function (DRV-09) ,I IM Sensorless, P PM Sensorless
*O/X: Write-enabled during operation
Code
Comm.
Address
Name LCD Display Setting Range
Initial
Value
Property
*
V/F SL Ref.
00
-
Jump Code
Jump Code
1-99
20
O
O
I/P
p.52
01 0h1201
Auxiliary
reference
source
Aux Ref Src
0
None
0:None X O I/P -
1
V1
3
V2
4
I2
6
Pulse
02
3
0h1202
Auxiliary
command
calculation type
Aux Calc Type
0
M+(G*A)
0:
M+(GA)
X O I/P -
1
Mx (G*A)
2
M/(G*A)
3
M+[M*(G*A)]
4
M+G*2(A-
50%)
3
Displayed when BAS-01 is not set to 0 (None)

Table of Contents

Other manuals for LSIS S100