80
Learning Basic Features
Code
Description
[An example of a multi-step operation]
Speed
Fx/Rx
P7
P6
P5
0 - - -
1
-
-
2
-
-
3
-
4 - -
5
-
6
-
7
IN-89 InCheck Time
Set a time interval for the inverter to check for additional terminal block inputs
after receiving an input signal.
After adjusting IN-89 to 100ms and an input signal is received at P6, the inverter
will search for inputs at other terminals for 100ms, before proceeding to
accelerate or decelerate based on P6’s configuration.