Chapter 1 General
1- 10
1.4.4 Allocation of compact type (S/H type) output signal
(1) Allocation of output signal
In case of using built-in positioning of XGB compact standard/high-end type main unit, output signal is
allocated as follows.
Signal name
Input contact point no.
Operation content
Reference
Pulse + Direction
mode
CW/CCW mode
Axis
XBC-
DN
□□
H
XBC-
DN(P)
□□
S(U)
XEC-
DN(P)
□□
S(U)/H
Pulse output
(CW output)
X
axis
P00020 P00040 %QX0.0.0
Positioning X axis
pulse string
(Open collector
output)
X axis CW pulse
string output
(Open collector
output)
Low Active and
High Active is
selectable in
parameter
setting
Y
axis
P00021 P00041 %QX0.0.1
Positioning Y axis
pulse string
(Open collector
output)
Y axis CW pulse
string output
(Open collector
output)
Direction
output
(CCW
output)
X
axis
P00022 P00042 %QX0.0.2
X axis direction
output contact
point
(Open collector
output)
X axis CCW pulse
string output
(Open collector
output)
Y
axis
P00023 P00043 %QX0.0.3
Y axis direction
output constant
point
(Open collector
output)
Y axis CCW pulse
string output
(Open collector
output)
External 24V
X/Y
axis
P
Terminal for external power (12/24V) to
implement the transistor
Input
common
X/Y
axis
COM0 Output common terminal
* Standard type (XBC-DN(P)□□S(U)) supports only “pulse + direction mode”.
(2) Wiring example of external input signal
In case of using positioning function of XGB high-end basic unit, wiring example is as follows.