363-206-305 Trouble Clearing:
TAP-116
Issue 3, June 2000 Page 1 of 6
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Clear Trouble During Network Element
Program Upgrade
1.
NOTE:
Program installation may fail due to failure of communication link between
PC and DDM-2000, failure of the floppy disk or hard disk on the PC,
failure or loss of power in the PC, or failure of the SYSCTL. See
ins-prog: and cpy-prog: command pages in the Commands and
Reports section of Volume 1 of this manual for other failure indications.
Was the following message received?
SCSN
/* Status, invalid Command SequeNce. */
/* Incompatible software.*/
If YES, continue with Step 2.
If NO, proceed to Step 4.
2. Indications are that you are trying to download software that is incompatible
with the shelf type (for example, DDM-2000 OC-3 software into a DDM-2000
FiberReach shelf). Find compatible software.
If you need assistance, notify your supervisor, your local technical support
organization, or call Lucent Technologies RTAC, per local operating
instructions.
3. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
4. Was the following message received?
/* Status, execution stopped. */
/* Communication link could not be established.
Please connect PC with program to be installed and start
again. */
If YES, continue with Step 5.
If NO, proceed to Step 6.