TAP-116
: Trouble Clearing 363-206-305
Page 2 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
5. Indications are that the ins-prog:tid or command was not executed from
a PC. A program upgrade to the near end DDM-2000 cannot be performed
with a CIT. Use PC to repeat software download.
6. Was the following message received?
/* Status, execution stopped. */
/* Communication link cannot be established.
Please connect PC with DDM-2000 upgrade program and start
again. */
If
YES
, continue with
Step 7
.
If
NO
, proceed to
Step 8
.
7. Indications are that the PC is not functioning properly, the disk drive is
inoperable, the diskette has been removed, or the program has previously
been erased from the
SYSCTL
. Check that the PC is operating properly and
the diskette has not been removed. Check PC to CIT port connections.
Has program installation procedure been tried more than once?
If
YES
, continue with
Step 8
.
If
NO
, proceed to
Step 15
.
8. Was the following or similar message received?
ins-prog:tid DENY
SSTP
/* Status, execution stopped. */
/* Far end not responding.
If
YES
, continue with
Step 9
.
If
NO
, proceed to
Step 12
.
9. Is
SYSCTL
circuit pack installed at far end?
If
YES
, proceed to
Step 12
.
If
NO
, continue with
Step 10
.
10. Determine reason
SYSCTL
is not installed. The
SYSCTL
must be installed to
upgrade program. Reinstall the
SYSCTL
and repeat the program installation
procedure.
11.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.