363-206-305 Detailed Level Procedure:
DLP-503
Issue 3, June 2000 Page 1 of 2
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Install/Remove Lightguide Buildout
1.
!
WARNING:
Unterminated optical connectors may emit invisible laser radiation. Eye
damage may occur if beam is viewed directly or with improper optical
instruments. Avoid direct exposure to beam.
!
CAUTION:
Use static ground wrist strap whenever handling circuit packs or working
on DDM-2000 FiberReach terminal to prevent electrostatic discharge
damage to sensitive components.
Is buildout being installed or removed?
If installing, continue with Step 2.
If removing, proceed to Step 5.
2. Remove protector caps and plugs (if equipped) from buildout and buildout
block.
3. Align lightguide buildout locking tab with slot in buildout block (unlocked
position), push in, and rotate clockwise until locked into position. Refer to the
appropriate figure (Figure 1, 2, or 3) for the specific buildout type.
Figure 1. ST-Type Universal Buildout