363-206-305 Detailed Level Procedure:
DLP-521
Issue 3, June 2000 Page 1 of 4
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Connect CIT and Establish Session
1.
!
CAUTION:
You must wear an ESD wrist strap plugged into the grounding jack on the
right side of the assembly whenever working with the DDM-2000.
Connect CIT to the RS-232C CIT connector on the DDM-2000 User Panel or
rear CIT connector.
2. Turn on CIT and set terminal parameters as follows (consult your terminal's
manual for setup procedures):
Full duplex
8 data bits
1 start bit
1 stop bit
No flow control
Baud rate setting is automatically set by DDM-2000 when connection is
made.
3.
NOTE:
To set baud rate automatically, enter two carriage returns (<cr>), two
lower case "a"s (aa), or two upper case "A"s (AA). All other characters
are ignored.
Enter two carriage returns.
Response: CIT prompts with:
/* Enter a shelf number from 1 to 8 */
shelf [default=1] =
4.
NOTE:
Entering just a carriage RETURN at the shelf prompt will connect you to
the default shelf physically connected to the CIT.
Enter the shelf number and/or carriage RETURN for the shelf being accessed.
Response: CIT prompts with login <