DLP-525
: Detailed Level Procedures 363-206-305
Page 2 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
2. Observe one of the following indications on the FE ID display. Note the
indication and follow the suggested procedure.
Letter "P" in FE ID Display:
Indicates no software installed in
SYSCTL
. Software must be
downloaded locally using these procedures.
Continue with
Step 3
.
Letter "P." in FE ID Display:
Letter "
P
" followed by a period (
.
) indicates a previous download
attempt has failed. New software must be downloaded locally using
these procedures.
Proceed to
Step 6
.
Letter "U" in FE ID Display:
Indicates
SYSCTL
switches
S1
and
S2
are not set properly for type
of shelf being equipped.
Remove
SYSCTL
. Repeat procedures of
DLP-539
to correct switch
settings and to install
SYSCTL
.
Letter "E" in FE ID Display:
Indicates
SYSCTL
must be replaced.
Get replacement
SYSCTL
and repeat procedures of
DLP-539.
Letter "F" in FE ID Display:
Indicates
SYSCTL
faceplate latch is not fully latched.
Unplug
SYSCTL
and repeat procedures of
DLP-539
. Ensure you
properly latch the faceplate when installing
SYSCTL
.
Flashing Letter "L" in FE ID Display:
Indicates a low voltage condition (brownout) on the shelf.
Clear trouble using
Trouble Clearing: TAP-119
.