363-206-305 Detailed Level Procedure:
DLP-529
Issue 3, June 2000 Page 3 of 6
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
11. On test set connector head, remove battery lead and check for blown fuse(s).
12. Is fuse(s) blown?
If YES, continue with Step 13.
If NO, proceed to Step 14.
13. Replace fuse(s) and repeat from Step 5.
14.
NOTE:
Test set may be used for testing using one, two, three, or all four BATT
plug positions.
There is a defective test set or connector head. Note defective BATT plug
position(s). Continue with test procedures using remaining BATT plugs.
15. Does test set TIME display indicate 00 MIN:00 SEC without blinking?
If YES, continue with Step 16.
If NO, proceed to Step 35.
16. Does status display indicate which battery was connected, status (GOOD or
REPLACE) of the battery, and is READY indicator lit?
If YES, continue with Step 17.
If NO, proceed to Step 35.
17. Does status display indicate GOOD or REPLACE?
If YES, proceed to Step 19.
If NO, continue with Step 18.
18.
!
DANGER:
A high discharge current is present at connector head if
TESTING
indicator is lit. Batteries must not be connected or disconnected when
TESTING
indicator is lit.
Battery pack is defective. Ensure that TESTING indicator is not lit (READY
indicator lit), unplug and set aside defective battery pack, and repeat from Step
5.