DLP-536
: Detailed Level Procedure 363-206-305
Page 2 of 14 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Verify that no DCC failures or transmission failures (OC-1 LOS, OC-3 LOS,
OC-12 LOS, flashing
OLIU FAULT
LEDs, etc.) are present on the network
element or system receiving the program. For software upgrade compatibility,
see Table A..
3.
NOTE:
If you are using a PC operating in a
Windows
*
environment, you must
exit
Windows
and restart your PC in
MS-DOS
mode before performing
these download procedures. For example, if your PC is running
Windows
95
you must exit
Windows
by clicking on the
Start
button, then
Shut
Down
, then
Restart the computer in
MS-DOS
mode
.
Obtain equipment, check software, and connect PC for download.
Reference: DLP-541
Table A – DDM-2000 FiberReach Inservice Software Upgrade Compatibility
(Note)
Current Release
Upgrade to
*
* When doing an upgrade, it is recommended that the
latest point release of software be used, if possible.
4.0
1.0.n (OC-1) C†
2.0.n (OC-1) C†
2.1.n (OC-1) C†
2.2.n (OC-1, OC-3) C†
3.0.n (OC-1, OC-3) U
3.1.n (OC-1, OC-3) U
Note:
All DDM-2000 FiberReach shelves in a
subnetwork should be using TARP Release 3.0 or 4.0
software.
C
Requires local software download only to upgrade
the system.
U
Requires local or remote software download only
to upgrade the system.
†
Incompatible OSI stack requires special
considerations. See LTP 824-102-144,
Lucent
Technologies 2000 Product Family, Operations
Interworking Guide
for TARP Releases, for special
considerations.
* Registered trademark of Microsoft Corporation.