363-206-305 Detailed Level Procedure:
DLP-536
Issue 3, June 2000 Page 3 of 14
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
4. Observe one of the following indications on the FE ID display. Note the
indication and follow the suggested procedure.
Letter "P" in FE ID Display:
Indicates no software installed in SYSCTL. Software must be downloaded
locally using these procedures.
Continue with Step 5.
Letter "P." in FE ID Display:
Indicates corrupted application software. New software must be force
downloaded locally using these procedures.
Proceed to Step 18.
FE ID Display Blank:
Indicates compatible software is installed in OHCTL and SYSCTL. This
procedure assumes the installed software version is not the correct
version. (Depress ACO button for longer than 2 seconds to display
software version on the FE ID display.)
Proceed to Step 8.
Letter "C" in FE ID Display:
Indicates software is installed in SYSCTL, but it will not support the
current shelf provisioning.
Proceed to Step 22.
Letter "U" in FE ID Display:
Indicates SYSCTL Switch S1 is not set properly for type of shelf being
equipped.
Remove SYSCTL. Repeat procedures of DLP-501 to correct switch
settings and to reinstall SYSCTL.
Letter "E" in FE ID Display:
Indicates SYSCTL must be replaced.
Get replacement SYSCTL and repeat procedures of DLP-501.