DLP-536
: Detailed Level Procedure 363-206-305
Page 12 of 14 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
27. Perform the following:
A. Check that the DDM-2000 is connected to the PC through the
COM
port.
If it is not, reconnect the PC to DDM-2000 using the
COM
port and repeat
this procedure.
B. Ensure first (number 1) disk of program being installed is inserted, if using
floppies.
C. Ensure diskette is inserted in correct drive.
D. Ensure the proper command was used to go to the drive with the diskette
or to the proper directory containing the software.
E. Check for invalid COM port. Exit TERM (
Alt
F2
), then restart TERM using
term COM1
or
term COM2
.
F. If the download still does not start, as indicated by the In progress
message and rows of dots, within 2 minutes after the
P
appears in the
FE
ID
display, change the baud rate as follows and repeat this procedure: if
the baud rate is currently set to 9600, change it to 4800 or if the baud rate
is currently set to 4800, change it to 9600. The baud rate is changed by:
1. Momentarily depress the
Alt C
keys.
2. Use the RETURN key to move to the "Speed" field.
3. Press the "Space" bar until the desired rate appears.
4. Momentarily depress the
Esc
(Escape) key to activate the new
baud rate.
G. If the download still does not start, refer to
Trouble Clearing: TAP-116
.
28.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.