DLP-539
: Detailed Level Procedure 363-206-305
Page 2 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
3.
NOTE:
Steps 4
and
5
must be performed without unnecessary delays.
Familiarize yourself with these steps before continuing with the
procedure.
Read Steps 4 and 5 before proceeding.
4.
!
CAUTION:
Take care to avoid damaging the LEDs that protrude through the opening
in the faceplate of the
SYSCTL
.
NOTE:
The
UPD/INIT
pushbutton on the
SYSCTL
is recessed to prevent its
accidental operation. You will need a small pointed object such as a
ballpoint pen to operate it.
NOTE:
Ignore the
MJ
,
MN
, and
NE ACTY
LEDs on the User Panel.
Read the remainder of this step and Step 5 before installing the SYSCTL
,
then seat the
SYSCTL
.
If the following responses do not occur, proceed to
Step 6
.
Response:
FAULT
LED on
BBG8/BBG8B SYSCTL
lights and
ABN
LED on the User Panel lights after approximately 5
seconds.
MJ
and
NE
LEDs may light or flash briefly.
FAULT
LED on the
SYSCTL
goes off after approximately
5 seconds.
ABN
LED goes off after approximately 15
seconds. Approximately 1 minute and 30 seconds after
the
ABN
LED goes off and the
CR
LED on the User Panel
begins to flash.