363-206-305 Detailed Level Procedure:
DLP-539
Issue 3, June 2000 Page 3 of 4
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
5. Momentarily depress the UPD/INIT button on the SYSCTL while the CR LED
is flashing (you have 10 SECONDS to do this).
If the following responses do not occur, continue with Step 6.
Response: CR LED on the User Panel stops flashing when the
UPD/INIT button is pressed.
ABN LED on the User Panel are lighted after
approximately 15 seconds. ABN LED goes off after
approximately 30 seconds. Approximately 1 minute and
45 seconds after the ABN LED goes off, the CR LED on
the User Panel flashs again. DO NOT depress UPD/INIT
pushbutton again when the CR alarm LED flashes.
Initialization may take 2-3 minutes.
6. Observe one of the following indications in the FE ID display. Note the
indication and follow suggested procedure:
• Nothing displayed in the FE ID display indicates that compatible software
is installed in the SYSCTL.
Proceed to Step 9.
• The letter "P"displayed in the FE ID display indicates that no software is
installed in the SYSCTL. If the "P" is followed by a period "P.", it means
that a previous download attempt has failed and a new software download
will have to be attempted either locally or remotely using the
ins-prog:tid or cpy-prog:tid command. If there is no period "P"
the software can only be downloaded locally.
Continue with Step 7.
• The letter "U" displayed in the FE ID display indicates that SYSCTL
Switch S1 is not set properly for type of shelf being equipped.
Remove SYSCTL and repeat this procedure from Step 1.
• The letter "E" displayed in the FE ID display indicates that the SYSCTL
must be replaced.
Get replacement SYSCTL and repeat this procedure from Step 1.