DLP-539
: Detailed Level Procedure 363-206-305
Page 4 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
The letter "
F
" displayed in the
FE ID
display indicates that the
SYSCTL
faceplate latch is not fully latched.
Unplug the
SYSCTL
and repeat this procedure from
Step 3
. Ensure you
properly seat the faceplate latch when you seat the
SYSCTL
.
A flashing letter "
L
"displayed in the
FE ID
display indicates a low voltage
condition (brownout) on the shelf.
Use
TAP-119
to clear brownout condition.
7. Find circuit packs with compatible software and repeat this procedure, or
install new software using the procedures of
DLP-525
.
8.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.
9. Retrieve generic software version ID by depressing the
ACO
button longer
than 2 seconds and observing version code on the
FE ID
display.
10. Is proper software version installed?
If
YES
,
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.
If
NO
, continue with
Step 11
.
11. Find circuit packs with the correct software and repeat this procedure or install
new software using the procedures of
DLP-525
.
12.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.