MAN B&W 8.09
Page of
MAN Diesel
MAN B&W S80ME-C 198 51 48-4.0
Hydraulic Control Oil System, S80ME-C
Fig. 8.09.02: Hydraulic control oil system
178 54 39-0.0
Cylinder No.: 6 7 8
r/min 76 76 76
kW
23,280
27,160 31,00
Hydraulic Control Oil tank:
Volumen, approx. m³ 5 5.5 6.5
Hydraulic Control Oil Pump:
Pump capacity m³/h 75 90 100
Pump head bar
Delivery pressure bar
Design temperature °C 70 70 70
Oil viscosity range cSt 15 - 90 15 - 90 15 - 90
Pressure Control Valve:
Lubricating oil ow m³/h 75 90 100
Design pressure bar
Adjustable pressure bar 2 - 2 - 2 -
Design temperature °C 55 55 55
Oil viscosity range cSt 15 - 90 15 - 90 15 - 90
Hydraulic Control Oil Cooler:
Heat dissipation kW 275 315 365
Lubricating oil ow m³/h 75 90 100
Oil outlet temperature °C 5 5 5
Design pressure, oil side bar
Oil pressure drop, max bar 0.5 0.5 0.5
Cooling water ow m³/h 0 6 53
S.W. inlet temperature °C 32 32 32
F.W. inlet temperature °C 36 36 36
Water press. drop, max. bar 0.2 0.2 0.2
Temperature Controlled Three-way Valve:
Lubricating oil ow m³/h 75 90 100
Design pressure bar
Temperature set point °C 5 5 5
Design temperature °C 70 70 70
Oil press. drop, max. bar 0.3 0.3 0.3
Hydraulic Control Oil Filter:
Lubricating oil ow m³/h 75 90 100
Absolute neness μm 50 50 50
Design temperature °C 55 55 55
Design pressure bar
Oil press. drop, max. bar 0.3 0.3 0.3