MAN B&W 2.08
Page  of 2
MAN Diesel
198 68 15-2.0MAN B&W ME/ME-C/ME-GI/ME-B engines
K98MC/MC-C6/7, S90MC-C7/8, K90MC-C6, S80MC6,
S80MC-C7/8, K80MC-C6, S70MC6, S60MC6, S50MC6,
S46MC-C6/7, S42MC7, S35MC7, L35MC6, S26MC6
With
p
max
adjusted
Without
p
max
adjusted
Parameter
Condition
change
SFOC
change
SFOC
change
Scav. air coolant
temperature
per 0 °C rise
+ 0.60% + 0.4%
Blower inlet tem-
perature
per 0 °C rise
+ 0.20% + 0.7%
Blower inlet
pressure
per 0 mbar
rise
 0.02%  0.05%
Fuel oil lower
caloric value
rise %
(42,700 kJ/kg)
.00%  .00%
SFOC reference conditions and guarantee
SFOC guarantee
The SFOC guarantee refers to the above ISO
reference conditions and lower caloric value. It
is guaranteed for the powerspeed combination
in the matching point (O) and the engine running
‘Fuel economy mode’ in compliance with IMO NO
x
emission limitations.
The SFOC guarantee is given with a tolerance
of 5%
Recommended cooling water temperature
during normal operation
In general, it is recommended to operate the main
engine with the lowest possible cooling water
temperature to the air coolers, as this will reduce
the fuel consumption of the engine, i.e. the engine
performance will be improved.
However, shipyards often specify a constant
(maximum) central cooling water temperature
of 36 °C, not only for tropical ambient tempera-
ture conditions, but also for lower ambient tem-
perature conditions. The purpose is probably to
reduce the electric power consumption of the
cooling water pumps and/or to reduce water con-
densation in the air coolers.
Thus, when operating with 36 °C cooling water
instead of for example 0 °C (to the air coolers),
the specic fuel oil consumption will increase by
approx. 2 g/kWh.
SFOC at reference conditions
The SFOC is given in g/kWh based on the
reference ambient conditions stated in ISO
3046:2002(E) and ISO 5550:2002(E):
,000 mbar ambient air pressure
25 °C ambient air temperature
25 °C scavenge air coolant temperature
and is related to a fuel oil with a lower caloric
value of 42,700 kJ/kg (~0,200 kcal/kg).
Any discrepancies between g/kWh and g/BHPh
are due to the rounding of numbers for the latter.
For lower caloric values and for ambient condi-
tions that are different from the ISO reference
conditions, the SFOC will be adjusted according
to the conversion factors in the table below.
With for instance  °C increase of the scavenge
air coolant temperature, a corresponding  °C in-
crease of the scavenge air temperature will occur
and involves an SFOC increase of 0.06% if p
max
is
adjusted to the same value.