MAN B&W 16.01
Page of 8
MAN Diesel
MAN B&W ME/MEC engines 198 48 476.5
Auxiliary equipment system
The input signals for ‘Auxiliary system ready’ are
given partly through the Remote Control system
based on the status for:
• fuel oil system
• lube oil system
• cooling water systems
and partly from the ECS itself:
• turning gear disengaged
• main starting valve ‘open’
• control air valve for sealing air ‘open’
• control air valve for air spring ‘open’
• auxiliary blowers running
• hydraulic power supply ready
Monitoring systems
In addition to the PMI offline system required for
the installation of the ME engine, PMI online and
CoCoSEDS can be used to improve the monitor-
ing of the engine.
A description of the systems can be found in
Chapter 8 of the project guide.
Instrumentation
Chapter 8 in the Project Guide for the specic
engine type includes lists of instrumentation for:
• The CoCoSEDS online system
• The class requirements and MAN Diesel’s re-
quirements for alarms, slow down and shut
down for Unattended Machinery Spaces