MAN B&W 14.04
Page  of 
MAN Diesel
MAN B&W S80MC-C7, S80ME-C7 198 44 52-8.1
Table 14.04.01: Electric motor for auxiliary blower
The installed power of the electric motors are based on a voltage supply of 3x440V at 60Hz.
The electric motors are delivered with and tted onto the engine.
Electric Motor for Auxiliary Blower
Number of
cylinders
Number of auxiliary
blowers
Required power/blower
kW
Installed power/blower
kW
6
2
89 90
7 03 05
8 8 25
The number of auxiliary blowers in a propulsion
plant may vary depending on the actual amount of
turbochargers as well as space requirements.
For typical engine congurations, the required
power of the auxiliary blowers as well as the in-
stalled size of the electric motors are listed in Ta-
ble 4.04.0.