Page 129
Appendix| ASCII Communication with Sensor
optoNCDT 2300
A 6.3.1.5 Reset Counter
RESETCNT [TIMESTAMP] [MEASCNT] [TRIGCNT]
After the selected trigger edge comes into effect, the counter is reset.
- TIMESTAMP: resets the time stamp
- MEASCNT: resets the measurement value counter
- TRIGCNT: resets the trigger counter (after every 32 bit)
For the trigger modes NONE and SOFTWARE, the function for resetting the counters in the sensor comes into effect immediately after
the received command has been decoded. It is therefore not possible to establish temporal references between several sensors or to
have the counters in several sensors start simultaneously.
If EDGE or PULSE is selected as trigger type, the reset comes into effect with the next edge of the trigger signal.
A 6.3.1.6 Switching the Command Reply, ASCII Interface
ECHO ON|OFF
Setting the command reply at an ASCII command:
- ON: Command reply on, for example <Kdo> ok
->
- OFF: Command reply off, for example ->