Page 169
Appendix| EtherCAT
optoNCDT 2300
A 7.3.3.15 Object 2410h: Triggermodi
2410 RECORD Trigger mode
Subindices
0 VAR Number of entries 10 Unsigned8 ro
1 VAR Trigger mode 0 Unsigned8 rw
2 VAR Trigger edge/level 0 Unsigned8 rw
3 VAR Number of values per trigger 1 Unsigned16 rw
8 VAR Software triggering pulse FALSE BOOL rw
9 VAR Triggering measurement input / output FALSE BOOL rw
10 VAR Termination synchronous/trigger input 1 BOOL rw
Further details can be found in the section Triggering, see Chap. 7.6.1.
Trigger mode:
0 – No triggering
1 – Level triggering
2 – Edge triggering
3 – Software triggering
Trigger edge/level:
0 – At edge triggering: Falling edge; at level triggering: Low
1 – At edge triggering: Rising edge; at level triggering: High
Number of values per trigger pulse: Number of output data after a trigger pulse for edge or software triggering, 0...16382, 16383 =
infinite, 0 = Stop
Triggering measurement input or output:
0 – Triggering of measurement input
1 – Triggering of measurement output