5.5 Housing 2DR
ILD2300-2DR/R ILD2300-2DR/BL
Bolt connection Direct fastening
1.0 Nm
2.0 Nm
10 10
Housing Through
length
Screw Washer Tightening
torque per
screw
Screw depth Screw Tightening
torque per
screw
ISO 4762-A2 ISO 7089-A2 µ = 0.12 Minimum Maximum ISO 4762-A2 µ = 0.12
mm Nm mm mm Nm
2DR 30 M3 A3.2 1 - 10 M4 2
Fig. 15 Mounting conditions housing size 2DR
Recommended tightening torque
max. + 10 % permissible, not deceed min. -20 %!
The tightening torques specified in the table are approximate and may vary depending on the application.
The bearing surfaces surrounding the through-holes (mounting-holes) are slightly raised.
i
Mount the sensor only to the existing through-holes on a flat surface. Clamps of any kind are not permitted.
Housing sizes, see Chap. 3.4.