Page 43
Installation
optoNCDT 2300
5.6.6 EtherCAT
Through the Ethernet connection, the sensor can also be integrated into an EtherCAT environment.
Connect the sensor to a 2-port EtherCAT junction. Use a LAN cable with RJ-45-male connectors and the optionally available
cables PC2300-x/SUB-D and PC2300-0.5/Y.
PC2300-0.5/Y
optoNCDT
ERR
Power on
RUN
EtherCAT Ethernet
Laser off
In range
Midrange
Error
PC2300-x/SUB-D
Patch cable
PS2020
230
VAC
PE
N L
2-Port-EtherCAT-
junction
PC/Notebook
RS422
extension terminal
optoNCDT
ERR
Power on
RUN
EtherCAT Ethernet
Laser off
In range
Midrange
Error
PC2300-x/CSP
EtherCAT/CSP2008
EtherCAT/CSP2008
Run
BECKHOFF EK1122
X1
X2
LASER RADIATION
Do not stare into beam
Class 2 Laser Product
IEC 60825-1: 20xx-xx
P 1mW; P 1.2mW; t=0.5...542 s
0 P
μ
F=1.5...50kHz;
=670nm
LASER RADIATION
Do not stare into beam
Class 2 Laser Product
IEC 60825-1: 20xx-xx
P 1mW; P 1.2mW; t=0.5...542 s
0 P
μ
F=1.5...50kHz;
=670nm
Fig. 23 Measurement setup with EtherCAT connection
Alternatively, a connection via the RS422 extension terminal and the cable PC2300-x/CSP is possible. Both are available as optional
accessories. When a sensor ILD2300 is operated together with an Ethernet terminal, so the sensor ILD2300 is also setting to the
EtherCAT connection, see Chap. 8.5.

Table of Contents