Appendix| ASCII Communication with Sensor
optoNCDT 2300
A 6.7 Error Messages
If an error occurs with a command, then the error message is listed.
Error message Description
E01 Unknown command unknown command (rights to small to read).
E02 Wrong or unknown parameter type A transmitted parameter has a wrong type or a wrong number of parameters
were transmitted.
E03 not used
E04 I/O operation failed Can not write data to the output channel.
E05 The entered command is too long to be pro-
cessed.
The entered command with the parameters is too long
(greater than 255 bytes).
E06 Access denied. Login as expert is necessary.
E07 The answer is too long to be displayed by this
interpreter.
Answer is too long
E08 Unknown parameter unknown parameter
E09 not used
E10 not used
E11 The entered value is out of range or its format is
invalid.
The parameter value is out of range of the value range.
E12 The info-data of the update are wrong. For update only. The header of the update data contains an error.
E13 Error during the data transmission for the update. For update only. Error during update data transmission.
E14 Timeout during the update For update only: Timeout in the transfer of update data.
E15 Update file is too big. For update only: The update data are too large.
E16 not used
E17 Processing aborted. Upload data are too large. Process aborted.