Page 130
Appendix| ASCII Communication with Sensor
optoNCDT 2300
A 6.3.1.7 PRINT
Print
Print serves the output of all sensor settings.
Example of an answer:
GETUSERLEVEL USER OUTDIST_RS422 DIST1
STDUSER PROFESSIONAL OUTTHICK_RS422 NONE
TRIGGER NONE TERMOFF OUTADD_ETH NONE
TRIGGERLEVEL LOW OUTADD_RS422 NONE
TRIGGERCOUNT 1 OUTSTATISTIC_ETH NONE
SYNC NONE TERMOFF OUTSTATISTIC_RS422 NONE
IPCONFIG STATIC 169.254.168.150 255.255.255.0 169.254.168.1
MEASTRANSFER SERVER/TCP 1024
BAUDRATE 115200
MEASPEAK DISTA
MEASMODE DIST_DIFFUSE
MEASRATE 20
MATERIAL Vacuum
LASERPOW FULL
ROI 0 511
VSAVERAGE NONE
OUTVIDEO NONE
AVERAGE MEDIAN 9
MASTERMV NONE
STATISTICDEPTH ALL
OUTPUT NONE
OUTREDUCE 1 RS422 ETHERNET
OUTHOLD 200