EasyManua.ls Logo

MICRO-EPSILON optoNCDT 2300 - Error Handling

MICRO-EPSILON optoNCDT 2300
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 99
Value Output
optoNCDT 2300
9.5 Error Handling
The measurement output of the optoNCDT 2300 sensor in case of an error can be done in different ways:
- Error output: No holding the last measurement value, output of error value
- Keep last value infinitely: Infinite holding of the last measurement value
- Keep last value: Holding the last measurement value on n numbers of measuring cycles; then an error value (maximum of 1024) is
output. The number (n) of error values to be skipped can be specified via the web interface or command.
The command OUTHOLD sets the behavior of the measured value output, see Chap. A 6.5.1.3.