Appendix| ASCII Communication with Sensor
optoNCDT 2300
A 6.3.3.4 Number of Measurement Values Displayed
TRIGGERCOUNT <1...16382>|16383
- 1...16382: Number of measurement values which are displayed after trigger impulse when edge triggering or software triggering.
- 16383: Start continuous output of measurement values after trigger impulse when edge triggering or software triggering.
- 0: Stop triggering and discontinue continuous output of measurement values.
A 6.3.3.5 Software Trigger Pulse
TRIGGERSW
Creates a trigger pulse. Error message is displayed if “SOFTWARE” is not selected in trigger selection.
A 6.3.3.6 Trigger Output all Values
TRIGGEROUT [TRIGGERED|ALL]
- TRIGGERED: Factory setting; measurements output only, if the trigger is active.
- ALL: all measurements are output; Identification in bit 15 of the status word