Page 93
Digital Interfaces
optoNCDT 2300
8.4 EtherCAT
The sensor can communicate via the Ethernet connector (PC2300-0, 5 / Y) with an EtherCAT system.
Advantages:
- Fast data transmission,
- Parameterization of the sensor.
A connection of the sensor to an EtherCAT environment is possible with a 2-port EtherCAT junction or a RS422 extension terminal, see
Chap. 5.6.6 documentary about EtherCAT you also will find in the appendix, see Chap. A 7.
The description on the sensors XML file you will find on the supplied CD. See the file “optoNCDT2300.xml”.
8.5 Change Ethernet to EtherCAT
You can switch between Ethernet and EtherCAT via an ASCII command, see Chap. A 6.3.4.4, via a web browser, see Chap. 7.5.1, or
EtherCAT object, see Chap. A 7.11. The switching is done after restarting the sensor. Save the current settings before switching to
EtherCAT.
optoNCDT
ERR
Power on
RUN
EtherCAT Ethernet
Laser off
In range
Midrange
Error
EtherNET
optoNCDT
ERR
Power on
RUN
EtherCAT Ethernet
Laser off
In range
Midrange
Error
EtherCAT
ASCII command
“ETHERMODE ETHERCAT“
or
web interface
Restart
sensor
ASCII command
“ETHERMODE ETHERNET“
or
EtherCAT object “21B0:03“ and
EtherCAT object “2010:02“
Restart
sensor
LASER RADIATION
Do not stare into beam
Class 2 Laser Product
IEC 60825-1: 20xx-xx
P 1mW; P 1.2mW; t=0.5...542 s
0 P
μ
F=1.5...50kHz;
=670nm
LASER RADIATION
Do not stare into beam
Class 2 Laser Product
IEC 60825-1: 20xx-xx
P 1mW; P 1.2mW; t=0.5...542 s
0 P
μ
F=1.5...50kHz;
=670nm
The RS422 interface for transmitting an ASCII command is available both in Ethernet and EtherCAT mode.