Control Menu, Set Sensor Parameter
optoNCDT 2300
7.7 Loading, Saving, Extras
7.7.1 Loading/Saving Settings
All settings on sensor, for example measuring rate and averaging, can be permanently saved in application programs, so-called set of
parameters.
Load /
save
settings
Setup no.: 1 / 2 / 3 ... 8 Selection of the set of parameters to be load/save. The user selects a number when
loading/saving a complete configuration. Allows fast duplicating of sets of parameters.
Keep interface
settings
Checkbox You should load the interface settings only when the sensor is operated on different
networks respectively with different baud rates of the RS422 interface.
Activate Button If you press Activate the upper selected set of parameters is loaded from the internal
memory of the sensor.
Save setup Button The current sensor settings are stored in the selected set of parameters in the internal
memory of the sensor.
Manage
setups on
PC
Data selection for
transmission
Setup / mate-
rial data base
A set of parameters contains settings for measuring, for example measuring rate and
the interface settings. The material data base contains refractive indices of different
materials.
Setup no.: 1 / 2 / 3 ... 8 Selection of the set of parameters to be load/save. The user selects a number when
loading/saving a complete configuration. Allows fast duplicating of sets of parameters.
Export setup Button If you press Export the download manager of your browser opens and offers to save
the setting values in a specified file “setup. meo“ in the PC.
Keep interface
settings
Checkbox You should load the interface settings only when the sensor is operated on different
networks respectively with different baud rates of the RS422 interface.
Browse / import Button If you press Browse ... Windows opens the selection window to select a configuration
file saved in the PC. By opening the selected file in the selection window, the path is
cached. Loading the file will be effected by the Import setup button.